          3386
        
        
          Proceedings of the 18
        
        
          th
        
        
          International Conference on Soil Mechanics and Geotechnical Engineering, Paris 2013
        
        
          6 REFERENCES
        
        
          Température (°C)
        
        
          Déformation volumique
        
        
          Chauffage non drainé
        
        
          Refroidissement drainé
        
        
          Delage P, Le T.T, Tang A.M, Cui Y.J, Li X.L. 2007. Suction effects in
        
        
          deep Boom clay block samples. Géotechnique, 57 (1), pp 239–244.
        
        
          Fei Y. 1995. Thermal expansion. In: Thomas JA (ed) Mineral physics
        
        
          and crystallography: a handbook of physical constants. American
        
        
          Geophysical Union Online Reference Shelf 2, 29–44.
        
        
          Horseman S.T., Winter M.G., Entwistle D.C. 1987. Geotechnical
        
        
          characterization of Boom clay in relatio,n with the disposal of
        
        
          radioactive waste. Commission of European Communities, EUR
        
        
          10987.
        
        
          Lima A.,Romero E., Gens A., Muñoz J., Li X.L. 2010. Heating pulse
        
        
          tests under constant volume on Boom clay. Journal of Rock
        
        
          Mechanics and Geotechnical Engineering 2 (2), 124-128.
        
        
          McTigue D.F. 1986. Thermoelastic response of fluid-saturated porous
        
        
          rock, Journal of Geophysical Research, 91(B9), 9533–9542.
        
        
          Mohajerani M., Delage P., Sulem J., Monfared M., Tang A.M., Gatmiri
        
        
          B. 2012. A laboratory investigation of thermally induced pore
        
        
          pressures in the Callovo-Oxfordian Claystone. International Journal
        
        
          of Rock Mechanics and Mining Sciences, vol. 52, 112-121
        
        
          Figure 8. Variations volumiques lors des cycles en température.
        
        
          3.3
        
        
          
            Essai de refroidissement drainé
          
        
        
          L’essai de chauffage non drainé a été suivi d’un refroidissement
        
        
          drainé sous les mêmes valeurs de contraintes constantes. Il a
        
        
          permis la dissipation des surpressions thermiques et s’est traduit
        
        
          par une contraction de l’éprouvette de 0,47% (Figure 8).
        
        
          Monfared M., Delage P., Sulem J., Mohajerani M., Tang A.M. and De
        
        
          Laure E. 2011. A new hollow cylinder triaxal cell to study the
        
        
          behaviour of low permeable materials. International Journal of
        
        
          Rock Mechanics and Mining Sciences, 48 (4), 637-649.
        
        
          Palciauskas V.V, Domenico P. A. 1982. Characterization of drained and
        
        
          undrained response of thermally loaded repository rocks. Water
        
        
          Resour, Res 18(2), 281–290.
        
        
          Il est possible que la courbure en début de refroidissement
        
        
          soit due à des adaptations des capteurs LVDT au changement de
        
        
          sens de déplacement. En utilisant la section linéaire observée
        
        
          entre 55 et 25°C, on obtient un coefficient de contraction
        
        
          thermoélastique (et donc d’expansion thermoélastique)
        
        
          
        
        
          
            d
          
        
        
          = 1,26 × 10
        
        
          -4
        
        
          /°C comparable à la valeur de 1 × 10
        
        
          -4
        
        
          /°C
        
        
          trouvée par Sultan et al. (2002).
        
        
          Spang B. 2002. Excel Add-In for Properties of Water and Steam in SI-
        
        
          Units ,
        
        
        
          .
        
        
          Sultan N., Delage P. & Cui Y.J. 2002. Temperature effects on the
        
        
          volume change behaviour of Boom clay. Engineering Geology,
        
        
          Vol. 64, 2-3, 135-145.
        
        
          Vardoulakis I. 2002. Dynamic thermo-poro-mechanical analysis of
        
        
          catastrophic landslides. Géotechnique, 52 (3), 157-171.
        
        
          4 CONCLUSION
        
        
          Dans le cadre de recherches sur le comportement thermique de
        
        
          l’argile de Boom, roche-hôte potentielle pour le stockage à
        
        
          grande profondeur des déchets nucléaires en Belgique, un essai
        
        
          de chauffage non drainé suivi par un refroidissement drainé a
        
        
          été conduit sur un appareil triaxial cylindrique creux à faible
        
        
          longueur de drainage destiné à l’investigation expérimentale des
        
        
          phénomènes thermiques dans les argiles et argilites peu
        
        
          perméables.
        
        
          L’essai réalisé a permis d’identifier des paramètres
        
        
          importants dans l’étude et la modélisation du comportement
        
        
          thermique de l’argile dans le champ proche des galeries;
        
        
          Une valeur décroissante du coefficient de pressurisation
        
        
          thermique comprise entre 0,004 et 0,002 MPa a été déterminée.
        
        
          Cette décroissance, due en partie aux variations du coefficient
        
        
          de dilatation thermique de l’eau sous la contrainte considérée,
        
        
          résulte également des variations couplées avec la température de
        
        
          divers paramètres (dilatation thermique, compressibilité des
        
        
          phases solide et liquide, compressibilité drainée) qui ne sont pas
        
        
          encore tous identifiés. Les valeurs des paramètres obtenus sont
        
        
          en accord et complètent ceux déjà obtenus dans la bibliographie.
        
        
          Il en va de même de la valeur de dilatation thermoélastique
        
        
          obtenue après l’essai de refroidissement drainé.
        
        
          5 REMERCIEMENTS
        
        
          Les travaux décrits dans cet article proviennent de la thèse du
        
        
          premier auteur, co-financée par la Commission Européenne
        
        
          dans le cadre du projet européen TIMODAZ (F16W-CT-2007-
        
        
          036449, coordonné par Dr. Li Xiang-Ling d’EURIDICE) et
        
        
          l’Ecole des Ponts ParisTech. Nous remercions aussi Dr. Li pour
        
        
          avoir fourni les échantillons d’argile de Boom..